Line 66: Line 66:
      * //o3ds// and //​o3ds_maxstd//​ values have to be set in [[devel:​eubrewnetconfiguration|config]]      * //o3ds// and //​o3ds_maxstd//​ values have to be set in [[devel:​eubrewnetconfiguration|config]]
      * If not, a default value for std of 2.5 is used      * If not, a default value for std of 2.5 is used
-   - Filtered by ozone slant column / air mass  +     * For other measurements (ZS, FZ, FM, ...) you can set specific thresholds in //Data and Metadata// → //Data Processing//​ → //Rejection Criteria//. A std of 4 is used by default for ZS measurements. 
-      * //mu_ds// and //​mu_ds_value//​ values have to be set in [[devel:​eubrewnetconfiguration|config]], and the model of the Brewer is Mk II or IV and the stray light correction has not been defined +   - Filtered by ozone slant column / air mass 
-      ​* ​If not, default ​value of 3.5 is used+     ​For DS measurements, ​//mu_ds// and //​mu_ds_value//​ values have to be set in [[devel:​eubrewnetconfiguration|config]] 
 +       - If the limits are defined, they are used. 
 +       - If not, use these default ​values are used: 
 +         * Single (no stray correction): ​3.5 
 +         * Single (with stray correction):​ 6 
 +         * Double: 6 
 +     * For other ozone measurements in which the Stray Light correction ​is not defined (ZS, FZ, FM, ...), 3.5 is the default value for Single Brewers, and 6 for Doubles. You can also set a specific value in //Data and Metadata// → //Data Processing//​ → //Rejection Criteria//
    - The measures has valid hg (step change lees than 2) before and after (see [[devel:​brewerpythonmodule#​check_hg|Brewer Python Module (Check HG)]].    - The measures has valid hg (step change lees than 2) before and after (see [[devel:​brewerpythonmodule#​check_hg|Brewer Python Module (Check HG)]].
    - Filtered by Minimun Values: lesser Ozone values than Maximun are discarded    - Filtered by Minimun Values: lesser Ozone values than Maximun are discarded
Line 253: Line 259:
  
   * ''​file_access'':​ this is used to fill the ''​FILE_ACCESS''​ global attribute (see https://​evdc.esa.int/​documents/​1/​geoms-1.0.pdf,​ page 20, section 4.3.3). If more than one data center is specified, please separate their acronyms using only commas, e.g. ''​AVDC,​NDACC''​ (**do not** use semicolons! ''​AVDC;​NDACC''​ will not be interpreted correctly by the server!). If not specified, it defaults to ''​NDACC''​   * ''​file_access'':​ this is used to fill the ''​FILE_ACCESS''​ global attribute (see https://​evdc.esa.int/​documents/​1/​geoms-1.0.pdf,​ page 20, section 4.3.3). If more than one data center is specified, please separate their acronyms using only commas, e.g. ''​AVDC,​NDACC''​ (**do not** use semicolons! ''​AVDC;​NDACC''​ will not be interpreted correctly by the server!). If not specified, it defaults to ''​NDACC''​
 +
 +  * ''​individual'':​ write all individual measurements instead of daily means
  
 You can check the GEOMS-HDF files using the AVDC GEOMS QA checker available at https://​avdc.gsfc.nasa.gov/​index.php?​site=1473794367 You can check the GEOMS-HDF files using the AVDC GEOMS QA checker available at https://​avdc.gsfc.nasa.gov/​index.php?​site=1473794367