This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
codes:uvaccess [2024/04/09 11:58] jlsolano [Process UVL1_6] |
codes:uvaccess [2024/04/11 11:51] (current) jlsolano [UV Access Functions] |
||
---|---|---|---|
Line 2: | Line 2: | ||
This pages describes UV-specific access functions. For a general overview of EUBREWNET's access functions, as well as a description of common inputs, see the wiki page on the [[codes:dbaccess#access_functions|ozone access functions]] | This pages describes UV-specific access functions. For a general overview of EUBREWNET's access functions, as well as a description of common inputs, see the wiki page on the [[codes:dbaccess#access_functions|ozone access functions]] | ||
+ | |||
+ | See [[https://drive.google.com/file/d/1JPpzt8Ab_1A_QzWpZThd0xAXWe3l5ymM/view?usp=sharing|this presentation]] for a short overview of the UV configuration and processing levels. | ||
---- | ---- | ||
Line 213: | Line 215: | ||
==== Process UVL1_6 ==== | ==== Process UVL1_6 ==== | ||
* Function: UVL1_6 | * Function: UVL1_6 | ||
- | * Description: Starting from the level 1.5 UV product, process the data using the [[https://www.rivm.nl/en/uv-ozone-layer-and-climate/shicrivm|SHICRIVM code]] developed by Harry Slaper at the [[https://www.rivm.nl/en|National Institute of Public Health and the Environment (RIVM)]]. As of 2022-06-22, the output irradiances are calculated using the same generic slit function for all Brewer instruments. Output data is further filtered by SHICRIVM's QA/QC, retaining only measurements with GREEN and YELLOW flags. As in the case of level 1.5, output data is further filtered by the [[devel:eubrewnetconfiguration&#exclusion_list | UV Exclusion List]] | + | * Description: Starting from the level 1.5 UV product, process the data using the [[https://www.rivm.nl/en/uv-ozone-layer-and-climate/shicrivm|SHICRIVM code]] developed by Harry Slaper at the [[https://www.rivm.nl/en|National Institute of Public Health and the Environment (RIVM)]]. As of 2022-06-22, the output, shift-corrected irradiances are calculated using the same generic slit function for all Brewer instruments. Output data is further filtered by SHICRIVM's QA/QC, retaining only measurements with GREEN and YELLOW flags. As in the case of level 1.5, output data is further filtered by the [[devel:eubrewnetconfiguration&#exclusion_list | UV Exclusion List]] |
* Example: https://rbcce.aemet.es/eubrewnet/data/process/UVL1_6?brewerid=185&date=2021-09-15&format=text | * Example: https://rbcce.aemet.es/eubrewnet/data/process/UVL1_6?brewerid=185&date=2021-09-15&format=text | ||
* Input: | * Input: |